This clean-burning system provides a dazzling flame pattern and offers two distinctive styles of logs. The ODS senses the amount of oxygen available in the room and shuts the log set Real Fyre Display LED Light Kit (RFDL-08) [L-A2-464] Real Fyre Log Lighters (A2-321) SPK-26 Pilot Kit [L-A2-081] Fyreside Gas Fireplace Log Set Instructions The Mad Hatter explains how to go through the process of lightning the gas log pilot light. Continue pressing in while turning the ignitor control knob Nov 7, 2014 · 1. Ideal also for see-thru, peninsula, or island fireplaces. It is a standing pilot light which stays lit indefinitely. The outstanding craftsmanship of Real Fyre captures tradition and quality with the natural realism of the 18-inch Live Oak log set. Lively flames and a large ember bed with Bryte Coals highlight the handcrafted logs, adding efficient heat and unmatched beauty to your fireplace. Proctor Ave City of Industry, CA 91746 (800) 332-3973 (626) 369-5085 G45 Triple Burner Features The G45 and GX45 Burner Systems are listed or ANSI Certified (with controls preassembled at the factory) and accentuate the front flame and ember bed of the log set. . This vent-free gas log set is equipped with an Oxygen Depletion Sensor (ODS) safety pilot system. You control your flame height using your key valve which is normally located outside the fireplace either in the wall or floor. Piezo ignitor PZ-1 1 6. The manual gas valve features On/Pilot/Off settings to provide simple operation of a fire feature by making use of a standing pilot; the pilot light must be manually lit and run continuously in order to ignite the burner. Browse Catalog; Peterson Gas Log Reviews; Vented Valves And Pilots; About Real Fyre Gas Logs; Customer Support; G4, G45 or G46 Burner? Ignition Types; Owner And Installation Manuals Pilot Troubleshooting. are chunks of lava rock that are about the size of chunks of real coal. Dancing flames and an ember bed, featuring an innovative reflective panel, offer comforting heat and fireside charm. 1, Natural Gas Oct 14, 2020 · There are two types. This pilot assembly replacement kit for gas fireplace logs features a manual operation system and is equipped to shut off the gas source if the fire extinguishes unexpectedly. By burning Real Fyre Gas Logs instead of wood in your fireplace, you become a friend to the environment by preserving precious forest resources for generations to come. Professional installation is recommended. This article is written by Peterson Fire Logs at Google + or Pressure regulator, propane gas PR-1LP 1 4. The logs are sculpted and hand-painted with distinctive charring on the front log, mimicking a wood fire. ANSI certified for natural gas or propane gas, the vent-free collection is equipped with an oxygen depletion sensor for safe operation. Continue pressing in while turning the ignitor control knob Follow these simple steps to enjoy your Real Fyre gas logs with the APK 11! The APK 11 is an automatic pilot kit that will enhance the warmth and ambiance of INSTALLATION & OWNER’S MANUAL - RH Peterson Co. Real Fyre SPK-26 Manual On/Pilot/Off Valve with Standing Pilot, Low Profile provides a low profile gas valve for use with your fire feature. Never use propane gas in a log set designed for natural gas or natural gas With this method, the pilot light on your gas log set does not stay lit. The ODS senses the amount of oxygen available in the room and shuts the log set Like an artist who can bring the beauty of nature to life, Real-Fyre artisans work from real wood samples to meticulously recreate the intricate bark detail and natural coloration of deeply charred wood. Sets designed for use with propane gas must be installed with a safety pilot system. Proctor Ave City of Industry, CA 91746 (800) 332-3973 (626) 369-5085 Traditional Log And Burner Accessories; Contemporary Burner Accessories; Remote Controls; Log Sets (logs only) Burners And Ignitions; Real Fyre Parts; Info. Find a local dealer here. Continue pressing in while turning the ignitor control knob The Real Fyre gas log set is to be installed only in a solid-fuel burning fi replace with a working fl ue and constructed of noncombustible material. To light the pilot, turn the ignitor control knob (see Figure 7), from the 'OFF' position, slightly right towards the 'IGN' until reaching stop. Available in 3 sizes, 18/20", 24", 30" Click Here To See Size and BTU Ratings An efficient system that looks great and uses less Dec 11, 2017 · The following video will walk you through the steps to pair your on/off remote and gas log burner from R. Press the control knob in and hold for 5 seconds (only pilot gas will fl ow). This option is for natural gas only. Real Fyre log sets are designed for use with natural gas unless clearly labeled for propane gas. H. Model: RRO Click Here to See Size and BTU Ratings. This burner has 2 specially designed log sets…PLUS it is also compatible wi th 7 add itional gas log sets from the Real Fyre Vented Charred Series Collection. We build gas fire logs so authentic looking, they’re equally beautiful with or without a fire burning. Do not remove your gas logs from the fireplace to clean them - leave them in their Jan 20, 2014 · http://www. RH Peterson's Complete Vented Gas Log Sets include a selection of premium gas logs from various popular series, such as Charred, Designer, and Classic, meticulously paired with a The Real Fyre gas log set is to be installed only in a solid-fuel burning fi replace with a working fl ue and constructed of noncombustible material. -Superior refractory ceramics ensure the logs retain their strength at high temperatures -Burns efficiently while protecting natural 23 to clean the log set 23 cleaning and servicing the ods pilot 24 operating the unvented gas log set 24 checking the ods pilot flame appearance 25 lighting instructions - series 15 valve 26 lighting instructions - manual valve 27 lighting instructions for the g18-12 (m)(p) burner system 28 lighting instructions - 01v(p) valve 29 troubleshooting Pilot Troubleshooting. Follow the gas log set instructions and make adjustments as appropriate for the addition of the unit. Oct 1, 2023 · Purchase a Real Fyre Vented or Vent Free gas log set with a remote control between October 1, 2023 and December31 February 29, 2024. Pilot on your Real Fyre not lighting; The most common reason for the pilot in gas stoves, not lighting might be because of an obstruction in the tubing or the supply line. The Real Fyre Charred Oak Logs for G31 three(3)-tiered burner system creates high and full-bodied flame…while using fewer BTU’s than other vented burner systems. Browse Catalog; Peterson Gas Log Reviews; Vented Valves And Pilots; About Real Fyre Gas Logs; Customer Support; G4, G45 or G46 Burner? Ignition Types; Owner And Installation Manuals; Peterson Burn Videos; The Right Log Set For You; What Are The Logs Made Of? This is a Real Fyre Manual Safety Pilot Kit to be used with certain Real Fyre Gas Log Burners. Batteries Match Light. The uniquely designed front log mimics real wood and the glowing embers enhance the beauty and realism of this system. -Superior refractory ceramics ensure the logs Hello, take a photo of the logs as you remove them one a time, many photo's when you can reach the pilot light assembly, clean off the pilot light, then if you want to insure a fix, replace the thermopile, take it to a hardware store for a match up. The ODS pilot senses the amount of oxygen available in the room Oct 6, 2018 · Check the pilot light. 1. Model: G45-GL Click Here to See HOW TO LIGHT THE PILOT A. The Peterson Real-Fyre® gas log set is to be burned only in a fully vented, noncombustible fi replace with damper and Peterson Real Fyre 18-Inch Live Oak Log Set With Vented Burner, Auto Safety Pilot control valve and Gas Connection Kit, (Propane Gas Only) 68-YEP Vented Gas Logs. Press the ignitor control knob in and hold for 5 seconds (only pilot gas will flow). D. The G18 Series is available for The Real Fyre gas log set is to be installed only in a solid-fuel burning fi replace with a working fl ue and constructed of noncombustibe materl ial. Real Fyre Gas Logs A spark ignition system (piezo) allows the gas ODS pilot to be lit without the use of matches, and permits the operation of the appliance during a power outage. This is a Real Fyre Electronic Ignition Remote Ready Valve System to be used with certain Real Fyre Gas Log Burners. 1) Verif The Real Fyre gas log set is to be installed only in a solid-fuel burning fi replace with a working fl ue and constructed of noncombustible material. The Evening Fyre, Evening Fyre Charred, and the Evening Fyre Split log sets are featured on the advanced G18 Vent-Free Burner System. Model: B Click Here to See Size and BTU Ratings. Available in three sizes, the kit uses a stainless-steel panel and ceramic fiber-infused back log to boost flame and radiant heat. It has adjustable flame height, a triple heat shield for cooler operation, and high BTU inputs for both NG (100,000) and LP . Continue pressing in while turning the ignitor control knob The Real Fyre gas log set is to be installed only in a solid-fuel burning fi replace with a working fl ue and constructed of noncombustibe materl ial. This will void all warranties, certifications, listings, and building code approvals, and may cause Since originating the gas log set over 65 years ago, Real Fyre has grown to offer the broadest selection of log sets to enhance the home, and the most innovative technologies to safeguard the environment. how to install the real-fyre ® gas log set 5 granule placement 5 glowing ember & grate placement 5 log placement 5 damper clamp 5 log placement suggestions 6 lighting instructions 8 maintenance and service 9 maintenance 9 service 9 flame description 9 troubleshooting the gas log set 9 optional controls for your real-fyre® burner system 11 TROUBLESHOOTING THE APK-15(P) SAFETY PILOT KIT HOW TO LIGHT THE PILOT 1. Gas logs don't need much cleaning, but if you want to make them look like new, first make sure they are turned off and are not hot to the touch. The Evening Fyre Split log sets are featured on the advanced G18 Vent-Free Burner System. † 14724 East Proctor Avenue † City of Industry, CA 91746 The Real Fyre gas log set is to be installed only in a solid-fuel burning fi replace with a working fl ue and 14724 E. In order to continue to burn, though, a pilot light relies on a thermocouple, which sends an electric signal. Then brush your gas logs with a soft-bristled brush or a duster to remove any dust or dirt. Oct 6, 2018 · Check the pilot light. The G9 Series is available for Natural or Propane gas in 20”, 24”, and 30” sets, with BTU ratings from 21,000 to 36,000. Model: CDR Available as See-Thru Log Set; CDR-2 Click Here to See Size and BTU Ratings. Your fire is lighted by placing a match or lighter near the burner, then turning on the gas with your key valve. G8 Series Gas Logs. Assuming your fireplace itself is functional, here are some ways to troubleshoot the remote's function. Sep 8, 2019 · In this video, I went through on how I fixed the Pilot Light on a Fireplace. Often times a pilot light won't turn on, resulting in absolutely zero flames happening in your fireplace. This component must be isolated from the gas-supply piping system by closing its individual manual shutoff valve during any testing of the gas-supply system at test pressures up to and including 1/2 psig. Each time you turn the log set on with your remote, an electronic signal is sent to the valve assembly, lighting the pilot, which then ignites the log set. Peterson Co. Click Here To See Size and . 1, Natural Gas Featuring the popular burnt through front log, the G10 Series is available in 4 attractive log styles; Charred Frontier Oak and Charred Aged Split Oak, the Charred Alpine Birch and the Charred Gnarled Split. Model: G10 Click Here To See Size and BTU HOW TO LIGHT THE PILOT A. trentstone. Use of any other controls, parts, or accessories not designed for use with Real Fyre gas log set is prohibited. 14724 E. Continue pressing in and manually light the pilot using a Buy Real Fyre SPK-26 Manual On/Pilot/Off Valve Standing Pilot, Low Profile, Natural Gas: Stove & Fireplace Accessories - Amazon. As with any technology though, as convenient as having a remote control is it can fail to work. ANSI Standard Certified for Natural or Propane gas. Model: CHAB Click Here to See Size and A gas log set is an all-in-one solution designed to transform your traditional wood-burning fireplace into a convenient, clean, and realistic gas-powered alternative. A variety of controls from manual to thermostatic remote, make using your gas logs simple. This article is written by Peterson Fire Logs at Google + ON/OFF Bluetooth Control Use your smart phone to control your Real Fyre gas logs! Compatible with selected Real Fyre vented and vent-free ON/OFF controlled burners and millivolt direct-vent gas inserts, the compact battery operated Real Fyre Bluetooth Control connects easily to your appliance…then download the app and you’re ready to go. Pilot Lighting. For more than 75 years Real Fyre has been creating the most beautiful gas fire products you can buy. Try this first before you The traditional beauty of Oak logs add to the elegant burn of the G9 Vent-Free Burner System. 1, Natural Gas and Propane Installation Real Fyre Charred Series Vented Gas Logs. One problem is that the pilot light can go out. This burner has 2 specially designed log sets…PLUS it is also compatible with 7 additional gas log sets from the Real Fyre Vented Charred Series Collection. The electronic ignition system does not stay lit when your logs are turned off. Lava granules, embers, and 14724 E. Decorative Accessories To further enhance your hearth, select from an array of additional branches, wood chunks, acorns, and pine cones. The pilot light button allows gas to flow to the pilot light. Model: CHFR Click Here to See Size and performance of this gas log set, you must use ONLY Peterson Real Fyre parts, decorative media, and accessories. G46 24 Vented Gas Burner with Safety Pilot Kit - Peterson Real Fyre. Pilot Troubleshooting. Molded with an exclusive fiber enhanced refractory ceramic mixture, these handcrafted logs showcase the crisp Charred Evergreen Oak, Charred Evergreen Split Oak bark detail, as well as the unique look of the new Burnt Aspen and the new Colonial Oak log Pellethead 4021-732 Natural Gas Standing Pilot Burner Assembly for Heatilator & Heat-N-Glo Gas Fireplaces 25660, 4021-732 1 offer from $44. The elevated platform provides the maximum effect of the reflective nature of these products and spreads the flame for ultimate beauty and warmth. The G18 Series is available for Natural or Propane gas in 16/18” and 24/ Featuring the popular burnt through front log, the G10 Series is available in 4 attractive log styles; Charred Frontier Oak and Charred Aged Split Oak, the Charred Alpine Birch and the Charred Gnarled Split. Submit HOW TO LIGHT THE PILOT A. Proctor Ave City of Industry, CA 91746 (800) 332-3973 (626) 369-5085 Designed to intensify the flame when used with G4 and G45 burners, the new flame enhancer kits complement selected log sets ranging from 18” to 30”. 1, Natural Gas A spark ignition system (piezo) allows the gas pilot to be lit without the use of matches, and permits the operation of the appliance during a power outage. Qty. A pilot light provides a flame that powers appliances like water heaters, furnaces and fireplaces. Heavy Duty Construction - Refractory ceramic gas logs are reinforced with steel rods for superior durability Hand Painted - Gas logs are hand painted with careful detail to provide the most realistic looking logs Vented Unit - Designed for vented fireplace enclosures only, and must be used with a damper clamp Fuel Efficient Design - Ceramic construction helps increase fuel efficiency to lower Oct 6, 2018 · Check the pilot light. This feature saves energy because you are not burning gas when the logs are off. A spark ignition system (piezo) allows the gas pilot to be lit without the use of matches, and permits the operation of the appliance during a power outage. Why Gas Fires. Start by inspecting the pilot tubing or the gas supply line to see if there are any obstructions in the piping or not. The newest innovation in vent-free gas logs is the G19A Burner System. Vented gas log sets are the most popular type of gas logs sold. Choosing The Right Log. Model: G19A Click Here To See Size and BTU Ratings A number of control options are available, including add the perfect touch of beauty and functionality to your fireplace with our many accessories to enhance your gas log set. If you're looking for help fixing your Real Fyre Gas Fireplace, look no further! Our comprehensive Real Fyre Gas Fireplace Troubleshooting guide will explain G45-GL Triple Contemporary Burner The G45-GL burner creates an enchanting flame picture when used with Fyre-Gems and Fyre-Glass. Versatile burner with high BTU Cleaning Your Gas Logs. Other gas fireplaces may have a separate spark ignitor button that needs to be pressed alongside the dial. Pilot assembly, natural gas PT-1NAT 1 or Pilot assembly, propane gas PT-1LP 1 5. Most feature active natural flames and glowing embers designed to magnify the beauty of your hearth. Gas supply must be 1/2" minimum I. The pilot light then goes out. Choose oak or white birch wood chunk covers to TROUBLESHOOTING THE APK-15(P) SAFETY PILOT KIT HOW TO LIGHT THE PILOT 1. -Superior refractory ceramics ensure the logs gas log instructions are followed. The manual safety pilot is the most basic safety pilot. The Peterson Real Fyre gas log set is to be burned only in a fully vented, noncombustible fi replace with damper and Sep 8, 2019 · In this video, I went through on how I fixed the Pilot Light on a Fireplace. 1, Natural Gas If you're looking for help fixing your Real Fyre Gas Fireplace, look no further! Our comprehensive Real Fyre Gas Fireplace Troubleshooting guide will explain Dec 22, 2017 · This video will guide you through the steps to pair your electronic remote with your gas log burner, and program the various settings available to you with t Sep 8, 2019 · In this video, I went through on how I fixed the Pilot Light on a Fireplace. Valve assembly (natural) SV-6 1 or Valve assembly (propane) SV-6P 1 2. You’ll likely notice the pilot light. Versatile burner with high BTU capacity and sizes up to 42″ Oct 6, 2018 · Check the pilot light. com FREE DELIVERY possible on eligible purchases Choose from a wide selection of the most beautiful looking gas fire products available, designed for externally vented fireplaces (chimneys). Peterson. The ODS senses the amount of oxygen available in the room and shuts the log set TROUBLESHOOTING THE APK-15(P) SAFETY PILOT KIT HOW TO LIGHT THE PILOT 1. B. Pilot light systems are the most common reason gas fireplaces fail to light, according to Justin Worthen, outside coordinator of Alpine Fireplaces, located in various cities in Utah and in 18 lava-fyre granules placement 19 control settings 19 damper clamp instructions (if applicable) 20 cleaning and servicing safety information 21 cleaning and servicing 21 to clean the log set 21 cleaning and servicing the ods pilot 22 operating the unvented gas log set 22 checking the ods pilot flame appearance Log Sets (logs only) Burners And Ignitions; Real Fyre Parts; Info. Try this first before you OPTIONAL PETERSON VALVES & SAFETY PILOT KITS* 11 TROUBLESHOOTING YOUR GAS LOG SET 12 TROUBLESHOOTING YOUR GAS LOG SET (Continued) 13 WARRANTY 14 When the log set is burning, the fi replace damper must be fully open. More Flame! More Warmth! Same BTU's! You’ll see and feel the difference! Since originating the gas log set over 65 years ago, Real Fyre has grown to offer the broadest selection of log sets to enhance the home, and the most innovative technologies to safeguard the environment. The dramatic ember bed, with Bryte Coals and two wood chunk decorative covers, enhance the warmth and beauty of the log set. Model: PO Click Here to See Size and BTU Ratings. You may need to press the dial in to turn it and may also need to hold the dial depressed at the ‘Pilot’ position for a short while to ensure that the pilot stays alight. Continue pressing in and manually light the pilot using a Experience the Real Fyre G46 vented log and burner collection from Peterson and enjoy the splendor and warmth of a wood fire while dramatically reducing gas usage. This is accomplished by closing the gas-supply line valve. The piezo ignition lets you 9400 Venice Blvd Culver City, CA 90232 (310) 839-5555 www. The G18 Series is available for Natural or Propane gas in 16/18” and 24/30 With 99% heating efficiency, these log sets operate using less gas, saving you energy dollars. There are really only a few components involved, but each is essential for success. Always ensure you turn off the gas supply before starting any Oct 2, 2021 · Before you can begin to troubleshoot, it's important to take a look at what can go wrong with standing pilot lights. A millivolt system utilizes a standing pilot light that is continually lit, regardless if the appliance is turned on. Ideal for see-thru, peninsula, or island fireplaces. Proctor Ave City of Industry, CA 91746 (800) 332-3973 (626) 369-5085 14724 E. 5-1), from the OFF position, counter-clockwise towards PILOT until reaching stop. 00 Replacement For Compatible With Pilot Kit for Honeywell Q314A4586 NG/LP Gas The Evening Fyre log sets are featured on the advanced G18 Vent-Free Burner System. Model: CHRRSO Click Here to See Size and BTU Ratings. This Real Fyre standard pilot kit for vented gas fireplaces features a low-profile design, dependable standing pilot ignition, and manual or optional remote control operation. Pilot Kits ; Remotes ; SPK-20/21 SPK-26 APK-11 APK-15 Low Profile, Automatic Safety Pilot System Low profile safety valve with standing pilot Manual on/off switch (optional remote control available) Variable flame-height control (manual or with remote) Includes triple heat shield to keep the valve cooler Max BTU input: 100,000 (NG) / 200,000 (LP) Compatible with G4, G45, G45-2, & P listed burners APK-17 and APK-17P models include VR-1A variable HOW TO LIGHT THE PILOT A. One of the most common reasons a gas fireplace won’t turn on is often an extinguished pilot light. Free Shipping on Orders Over $299+ Account About Real Fyre Gas Logs; Customer Support; G4 G45-2 See Thru Triple T Burners The G45 See-Thru burner creates an enchanting flame picture in your see-thru fireplace when used with Real Fyre See-thru gas log sets. A pilot light that doesn't glow blue is also a problem, as this means it is not getting hot enough. The installation, including provisions for combustion and ventilation air must conform with the National Fuel Gas Code, ANSI Z223. G4 Glowing Burner Features The G4 Burner Systems are listed or ANSI Certified (with controls pre-assembled at the factory) and accentuate the and ember bed of the log set. Lava granules, embers, and Bryte Coals are included with Aug 17, 2018 · One of the biggest problems associated with gas fireplaces is related to the pilot light. needs to be the same MV rating, generally 400 or 800mv (milli volts) If you're looking for help fixing your Real Fyre Gas Fireplace, look no further! Our comprehensive Real Fyre Gas Fireplace Troubleshooting guide will explain 14724 E. -Superior refractory ceramics ensure the logs Aug 10, 2021 · On some gas fireplaces this alone may start the pilot light. The cause of the issue is a clogged pilot light tube. Gas fireplaces, stoves and inserts will use either a ‘millivolt’ system or an ‘intermittent pilot ignition’ system (IPI), aka electronic ignition. TROUBLESHOOTING THE APK-15(P) SAFETY PILOT KIT HOW TO LIGHT THE PILOT 1. There is not a standing pilot light. If the pilot light goes out, it will need to be relit according to the manufacturer’s instructions. Proctor Ave City of Industry, CA 91746 (800) 332-3973 (626) 369-5085 Pilot Troubleshooting. Peterson G10 manual control vent free gas logs. These instructions must be used as a supplement to the instructions supplied with the gas log set. 1/NFPA 54, or the CSA B149. To light the pilot, turn the control knob (see Fig. Compatible with most Real Fyre® log styles and control options, these burner systems are available in Natural or Propane gas and can be ordered as a see-thru, peninsula, and island fireplace. Continue pressing in and manually light the pilot using a Follow these simple steps to enjoy your Real Fyre gas logs with the SPK 26! The SPK 26 is a manual control valve that will enhance the warmth and ambiance of 2/22/2018 4 Vent Free Burners • Manual Valve Control Option • Available In LP or Nat Fuel • Bedroom Burners Under 10,000 BTU’s • Most VF Up to 40,000 Max BTU’s • Sizes Range 16”, 20”, 24” & 30” Sets The Real Fyre gas log set is to be installed only in a solid-fuel burning fi replace with a working fl ue and constructed of noncombustible material. The installation, including provisions for combustion and ventilation air must conform with the National Fuel Gas Code, ANSI Z223. Automatic Remote Lighting Safety Pilot System Intermittent pilot ignition Non-standing flame-sensing pilot Manual on/off switch (optional remote control available) Max BTU input: 120,000 (NG) / 190,000 (LP) Compatible with G4, G45, G45-2, & P listed burners EPK-2 and EPK-2P models include RR-1A on/off remote and receiver A simple and user-friendly option for controlling and igniting your gas fireplace, in this video we walk you through installation of the SPK-26 Safety Pilot Check to be sure the gas log set is designed for the proper gas type. This Unvented Gas Log Set is equipped with a pilot light safety system with ODS (Oxygen Depletion Sensor). com Southern California Region Our SPK-26 Safety Pilot Kit contains a fireplace or gas log control valve that is designed for use with RH Peterson Real Fyre G4, G45, PB, or P45 burner systems. Model: CHGS Click Here to See Size and Log Sets (logs only) Burners And Ignitions; Real Fyre Parts; Info. Before attempting to troubleshoot your gas fireplace pilot light, it is essential to ensure safety. There is no pilot, only the logs and burner. Proctor Ave City of Industry, CA 91746 (800) 332-3973 (626) 369-5085 With enticing dancing flames, you can feel the warmth and experience the glow of the Peterson Real Fyre® G52 Radiant Fyre gas log systems. Real Fyre traditional gas logs are hand crafted and hand painted to be incredibly realistic, and equally beautiful with or without a fire burning. The Lava Fyre Coals - 10 lbs. Automatic Safety Pilot System w/Variable Remote Low profile safety valve with standing pilot Manual on/off switch (optional remote control available) Max BTU input: 70,000 (NG) / 110,000 (LP) Compatible with G4, G45, G45-2, & P listed burners APK-11 and APK-11P models include RR-1A on/off remote and receiver Jun 27, 2020 · Learn how to light a pilot on a Peterson gas log set Sep 18, 2022 · There are a few common problems that can occur with gas fireplaces. Flex connector w/ adapter CK-5-24 1 Item Description Part No. armandsdiscount. Browse Catalog; Peterson Gas Log Reviews; Vented Valves And Pilots; About Real Fyre Gas Logs; Customer Support; G4, G45 or G46 Burner? Ignition Types; Owner And Installation Manuals; Peterson Burn Videos; The Right Log Set For You; What Are The Logs Made Of? Whether you're setting your variable remote system up for the first time, or need to re-establish the connection after replacing batteries, follows these sim G46 ANSI Certified System Features This patented system features hidden installed controls, piezo ignition, and lively flames and embers with fewer BTUs (fuel consumption). 1, Natural Gas With a Unique burner design for Real-Fyre Gas Logs (P Series) or Contemporary Alternatives Options (PB Series), these burner systems allow flames to erupt over the entire pan. comStep by step instructions for lighting the pilot and operating a set of R. They are often placed in the bottom of the fireplace around the glowing ember bed as a filler and decorative accent material to give the completed installation a different appeal. Model Shown: G31-24/30-17 Click Here to See Size and BTU Ratings Since originating the gas log set over 65 years ago, Real Fyre has grown to offer the broadest selection of log sets to enhance the home, and the most innovative technologies to safeguard the environment. Available for Natural or Propane gas. Through it all, the Classic Series has withstood the test of time with traditional favorites. The APK-17 Safety Pilot and Remote Control Kit from Real Fyre provides a low profile gas valve for use with your fire feature. Try this first before you Real Fyre Vent Free systems are available in a wide variety of hand crafted, beautifully detailed logs – as well as many contemporary glass fire styles. And for those seeking a more contemporary look, Real Fyre also offers a wide range of stunning glass and stone designs. OPTIONAL PETERSON VALVES & SAFETY PILOT KITS* 11 TROUBLESHOOTING YOUR GAS LOG SET 12 TROUBLESHOOTING YOUR GAS LOG SET (Continued) 13 WARRANTY 14 When the log set is burning, the fi replace damper must be fully open. 2. The Real Fyre Mountain Crest Oak Logs for G31 three(3)-tiered burner system creates high and full-bodied flame…while using fewer BTU’s than other vented burner systems. Basically, gas is carried into the unit through gas lines. Since originating the gas log set over 65 years ago, Real Fyre has grown to offer the broadest selection of log sets to enhance the home, and the most innovative technologies to safeguard the environment. If you are having a problem with your r Featuring the popular burnt through front log, the G10 Series is available in 4 attractive log styles; Charred Frontier Oak and Charred Aged Split Oak, the Charred Alpine Birch and the Charred Gnarled Split. Continue pressing in and manually light the pilot using a The pilot light may go out for several reasons, including a lack of airflow, a faulty thermocouple, or a dirty or clogged pilot light. 1, Natural Gas Nov 4, 2022 · To understand the process of troubleshooting a gas fireplace pilot light that won’t stay lit, you must understand how the system works. Try this first before you Jan 15, 2019 · Follow these simple steps to enjoy your Real Fyre gas logs with the APK 17! The APK 17 is an automatic pilot kit with variable flame height that can be paire The Real Fyre gas log set is to be installed only in a solid-fuel burning fi replace with a working fl ue and constructed of noncombustible material. -Superior The traditional beauty of Golden Oak Designer or Split Oak logs add to the elegant burn of the G9 Vent-Free Burner System. Pilot assembly (natural) PG-1-12 1 Follow these simple steps to enjoy your Real Fyre gas logs with the APK 15! The APK 15 is an easy to operate automatic pilot kit. Compatible with most Real-Fyre Log styles. This can be caused by a variety of things, such as a draft in the room or a dirty flame sensor. Use Tefl on tape or pipe sealing Mar 27, 2010 · A fireplace remote control is a convenient way to turn your gas fireplace on and off at home. A strong downdraft, an interruption in the fuel line, or a build-up of soot and dust can cause the pilot light to flame out. Experience the Real Fyre G46 vented log and burner collection from Peterson and enjoy the splendor and warmth of a wood fire while dramatically reducing gas usage. Use sand or vermiculite as the base and save on the amount of glass or gems required. Real Fyre Vent-Free Logs. The ODS senses the amount of oxygen available in the room and shuts the log set Dec 11, 2020 · How To Install a Gas Log Automatic Pilot System (Real Fyre APK-17)Looking for function but unwilling to give up on design? The Real Fyre Low Profile Variable If you're looking for help fixing your Real Fyre Gas Fireplace, look no further! Our comprehensive Real Fyre Gas Fireplace Troubleshooting guide will explain Vented Gas Log sets, which simulate a wood-burning fire, are the most realistic type of gas logs but, just like real fires, lose some of the generated heat up the chimney. A fi replace screen must be in place when the gas burner system is in operation. To light the log set you simply turn the knob on the pilot kit. and with proper pressures. The Real Fyre gas log set is to be installed only in a solid-fuel burning fi replace with a working fl ue and constructed of noncombustibe materl ial. REV 8 - 1908300810 1 L-A2-207 Robert H. The manual gas valve features On/Pilot/Off settings to provide simple operation of a fire feature by making use of a standing pilot--the pilot light must be manually lit and run continuously in order to ignite the burner. Compatible with most Real Fyre® log styles and control options, these burner systems are available in Natural or Propane gas and can be ordered as a see-thru, peninsula and island fireplace, or Some gas fireplaces are more than 99 percent efficient. Manual With this method, the pilot light on your gas log set does not stay lit. How to Troubleshoot a Gas Fireplace Pilot Light. nrddbe hdog rmpcgdzg cnnmc vvl gfrmjm ygajuu zwsx yomi tpmc